Trends in Green Chemistry Open Access

  • ISSN: 2471-9889
  • Journal h-index: 8
  • Journal CiteScore: 1.68
  • Journal Impact Factor: 1.21
  • Average acceptance to publication time (5-7 days)
  • Average article processing time (30-45 days) Less than 5 volumes 30 days
    8 - 9 volumes 40 days
    10 and more volumes 45 days
Reach us +32 25889658

Highly sensitive nano-membrane based potentiometric thin-film microchips responsive for some cations

EuroSciCon Conference on Chemistry and Green Chemistry Research
December 06-07, 2018 Amsterdam, Netherlands

Hassan Arida

Pharmacy College-Taif University, Saudi Arabia Hot Laboratories and waste management Center-Atomic Energy Authority, Egypt

Posters & Accepted Abstracts: Trends in Green chem

Abstract:

Microfabrication, electrochemical evaluation and analytical application of nanoparticles based thin film potentiometric microsensors were presented. The elaborated microchips were realized by integration of the nano-materials as sensitive layers on treated surface of thin-film gold square planner substrates. The investigated sensitive elements namely; lead dioxide (β-PbO2) nano-particles, potassium zinc hexacyanoferrate (II) (PZHCF) nano-cubes, titanium dioxide nano-particles were responsive for H+, Cs+, Cu2+, respectively. The merits offered by the nano-sensitive materials over the bulk sensitive based membrane include reasonable highly sensitivity (super Nernstian response), fast response time (~20 s), long term stability (4 months) and integration and automation feasibility. A highly sensitive thin-film pH micro-sensor has been fabricated by electrochemical deposition of nano-β-PbO2 on a gold microelectrode. The realized pH microchip electrode provides excellent linear response to pH values with a super sensitivity (84 mV/pH decade) over the pH 0.25-13 range. A nano-composite comprises PZHCF embedded in multi-walled carbon nano-tubes (CNTs) were used as sensitive layer in fabrication of thin-film Cs+ micro-sensor. The microchip provides high sensitivity (61±0.5 mV/concentration decade) towards cesium (I) ions covering the concentration range of 1×10-1- 1×10-5 mol L-1. Plasticized PVC membrane containing titanium dioxide nano-particles was deposited on thin-film microelectrode and tested as Cu2+ micro-sensor. The micro-fabricated chip shows good electrochemical properties Cu2+ (sensitivity of 23±0.5 mV/concentration decade) covering the range of 10-1-10-5 moleL-1. The micro-fabricated chips were successfully applied in the measurements of the corresponding cations in some real samples with high accuracy (97%) and precision (<3%).

Biography :

E-mail:

aridaha@hotmail.com